7.13.5.1.2.2. Type
  • Fast rebuild

    You can always activate the function.

    However, the following warning always appears:

    PARTdataManager

    If you save with the option 'Fast rebuild', then there will be no checks for accuracy while loading. This affects for e.g. changes in the configuration, back links and assembly tables. Back links will not be checked after loading either. Continue?

    Yes No

    [Warning]Warning

    Only use variables from the same branch!

    In the example on the right, P4 could ask for variables from P3, P2 and A, for example. However, P4 should not request variables [Variables] from P5, for example.

    Querying variables means using them in conditions, translation, rotation, value range assignment, etc.

    If this requirement is not met, do not use this feature!

    If there are problems with the building of an assembly, check if it is possible to avoid the error by deactivating the check box.

  • Append free connection points automatically

    • When used for assembly table project

      ???Templates which serve as basis for an Assembly Table Project, have to be created in a certain way. On this see .

    • When used for assembly configuration and assembly template

      The prerequisite for using the Automatically add free append points [Append free connection points automatically] option is that conditions [Conditions] ensure that only 1 line is possible in the append part. There is no harm if the option is activated even though the condition is not fulfilled; however, automatic construction is then impossible!

  • Resolve pattern recursive

    If there are no patterns, the option is irrelevant.

    If patterns are available and the option is not activated, patterns will not be built on. The

  • Forbid deletion of parts

    [Note]Note

    As of V11 only displayed at old assemblies which already used this feature. Do not use for new creation.

    Concerns assembly configuration and template. In the assembly table project, there is no access to the individual parts as these are controlled via the table.

    After activation, the corresponding context menu item is grayed out.

  • Merge to one part upon export

    [Note]Note

    As of V11 only displayed at old assemblies which already used this feature. Do not use for new creation.

    Currently only supported by Inventor. The evaluation takes place in CAD.

    extended attributes -> PSOL_MULTISOLIDPART
    0: Zu einem Teil verschmelzen
    1: Als Baugruppe exportieren
    z.B.
    EXTATTRVAL{
    NAME{ "PSOL_MULTISOLIDPART" }
     VALUE{ 0 }
    }

  • Invalidate changed tables even if the chosen line is still available.

    [Note]Note

    As of V11 only displayed at old assemblies which already used this feature. Do not use for new creation.

    (Only important for compatibility with version 7.4)

  • Export single part assemblies as single parts

    [Note]Note

    As of V11 only displayed at old assemblies which already used this feature. Do not use for new creation.

    In the special case that an assembly only consists of one part, this is exported as an individual part.